Expansion Joints

Comparison of Ratings, Features, and Available Options

EJ Styles Relative Movement Capability Relative Spring Forces Pressure Thrust on Piping System Available Features
Axial Angular Lateral Axial Angular Lateral Internal Flow Liner Types External Cover Redundant Ply Design End Connection Types
US
Unrestrained Single
YES SW, TW, FW, SD, TD YES YES BB, WE, FF, VF, LJ
TS
Tied Single
NO SW, TW, FW, SD, TD YES YES BB, WE, FF, VF, LJ
HS
Hinged Single
NO SW, TW, FW, SD, TD YES YES WE, FF, VF, LJ
SHS
Slotted Hinged Single
YES SW, TW, FW, SD, TD YES YES WE, FF, VF, LJ
GS
Gimbaled Single
NO SW, TW, FW, SD, TD YES YES WE, FF, VF, LJ
UU
Unrestrained Universal
YES SW, TW, FW, SD, TD YES YES BB, WE, FF, VF, LJ
TU
Tied Universal
NO SW, TW, FW, SD, TD YES YES WE, FF, VF, LJ
PBS
Pressure-Balanced, Elbow, Single
NO SW, TW, FW, SD, TD YES YES WE, FF, VF, LJ
PBU
Pressure-Balanced, Elbow, Universal
NO SW, TW, FW, SD, TD YES YES WE, FF, VF, LJ
PBI
Pressure-Balanced, In-Line
NO SW, TW, FW, SD, TD YES YES WE, FF, VF, LJ
EPS
Externally-Pressurized Single
NO FW INCL YES WE, FF, LJ
EPD
Externally-Pressurized Dual
YES FW INCL YES WE, FF, LJ
Legend: Higher / Lower / Moderate / Not Applicable

Options

Purge Ports
Packed Liner
Self Draining Liner